Heating oven with natural convection

The strength of the BINDER ED series heating oven: routine drying and sterilization applications up to 300 °C. Thanks to the gravity convection, thermal processes are highly efficient for this heating oven. A BINDER ED heating oven ensures fast, uniform drying.

Advantages:

  • Fast, even tempering
  • Wide temperature range
    FeaturesCustomer benefitsCharacteristics
    APT.line™
    • Quick drying
    • Identical test conditions throughout the chamber interior
    • Independent of specimen size and quantity
    APT.line™ for maximum precision
    • Uniform circulation even under full load
    • Homogeneous temperature conditions throughout specimen material
    Temperature range
    • Broad range of applications
    • Short warm up times
    Standard up to 300 °C
    • Large power reserves
    Inner chamber concept
    • Maximum occupational safety
    • Easy loading and unloading of specimen material
    • Easy cleaning
    Inner chamber made of stainless steel
    • Very tight door closure with 2-point door latch
    • Low heat dissipation due to 60 mm insulation
    • Rack with tilt protection
    • No permanent fixtures
    Standard equipment
    • Reliable, easy handling
    Comprehensive standards
    • Microprocessor control
    • Ergonomically positioned controller.
    • RS 422 interface
    • PT 100 temperature sensor
    Quality
    • Reliable devices with long service lives
    • Short delivery times
    • Minimal maintenance and operating costs
    Premium quality
    • Highly automated
    • Series production
    • High-quality materials, state-of-the-art production technology
    • High standard according to DIN 12880 (27-point measurement)
    Accessories and Services
    • Flexible solution in terms of size, type and equipment
    • Optimal solution for numerous applications
    • BINDER INDIVIDUAL for customer-specific solutions
    • Worldwide BINDER Service
    Comprehensive product portfolio
    • Size 23 to 720 liters
    • Additional product lines with humidity, light, CO2 or vacuum
    • Voltage variants (UL) and certificates
    • Various options: Door with viewing window, access ports, reinforced shelves, Data Logger Kits
    • Worldwide service network
    • Electronically controlled APT.line™ preheating chamber assuring temperature accuracy and reproducible results
    • Temperature range from 5 °C (9 °F) above ambient temperature to 300 °C (572 °F)
    • Digital temperature setting with an accuracy of one degree
    • DS control with integrated timer 0 to 99,59 hrs
    • Independent adjustable temperature safety device class 2 (DIN 12880), with visual temperature alarm
    • Adjustable ventilation by means of front ventilation flap slide and rear exhaust Ø 50 mm
    • Optional RS 422 Interface for APT-COM™ Data Control System communication software
    • Units up to 115 liters are stackable
    • 2 chrome-plated racks included
    • BINDER test confirmation
      ED 115
      Exterior dimensions
      Housing
      Width (mm)835
      Height (incl. feet/castors) (mm)705
      Depth (plus connections and fittings) (mm)645
      Depth (incl. connections and fittings) (mm)105
      Wall clearance, rear (mm)100
      Wall clearance, side (mm)160
      Exhaust duct (outer Ø mm)52
      Steam space volume (l)142
      Number of doors (ea.)1
         
      Interior dimensions
      Width (mm)600
      Height (mm)480
      Depth (mm)420
      Interior volume (l)115
      Racks (number standard/max.)2 / 6
      Load per rack (kg)20
      Permitted total load (kg)50
      Weight (empty) (kg)57
         
      Temperature data
      Temperature range approx. 5 °C above ambient temperature to (°C)300
      Temperature variation 1)
      at 70 °C (± K)1,5
      at 150 °C (± K)2,5
      at 300 °C (± K)4,5
      Temperature fluctuation at 70 °C (± K)0,3
      Warm-up time 2)
      to 70 °C (min.)15
      to 150 °C (min.)29
      to 250 °C (min.)66
      Recovery time after doors were open for 30 sec. 2)
      at 70 °C (min.)2
      at 150 °C (min.)9
      at 300 °C (min.)14
         
      Ventilation data
      Ventilation
      at 70 °C (x/h)12
      at 150 °C (x/h)10
      at 300 °C (x/h)10
         
      Electrical data
      IP protection class acc. to EN 60529IP 20
      Voltage (± 10%) 50 / 60 Hz (V)230
      Nominal power (kW)1,6
      Energy consumption
      at 70 °C (W)90
      at 150 °C (W)300
      at 300 °C (W)360
      1) without a viewing window
      2) At 98% of the set value

      All technical data are specified for units with standard equipment at an ambient temperature of +25 °C and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time.

0 komentar:

Posting Komentar

Free Website templateswww.seodesign.usFree Flash TemplatesRiad In FezFree joomla templatesAgence Web MarocMusic Videos OnlineFree Wordpress Themeswww.freethemes4all.comFree Blog TemplatesLast NewsFree CMS TemplatesFree CSS TemplatesSoccer Videos OnlineFree Wordpress ThemesFree CSS Templates Dreamweaver