The model 880 visible spectrophotometer is a digital microprocessor controlled instrument,
providing photometric absorbance, transmittance and concentration measurements with the
wavelength range of 330 to 1100 nm.
providing photometric absorbance, transmittance and concentration measurements with the
wavelength range of 330 to 1100 nm.
Specifications:
Wavelength Range 320-1100 nm
Bandwidth 2 nm
Wavelength Accuracy ± 1 nm
Wavelength Repeatability ± 0.35 nm
Photometric range - 0.300 -3.500 Abs
Measurement mode A/ %T / C
Factor 0.1 - 9,999.9
Photometric Accuracy 1.0% or 0.003A (from 0.000 to 2.500A), whichever is greater
Stability < 0.003A/hr at 500 nm after one hour warm-up
Baseline flatness ± 0.005 Abs (at 400 – 1100 nm)
Stray Light <0.1% at 340 nm by ASTM method
Light Source 12V halogen lamp
Detector Si photodiode
Wavelength scanning speed 4500 nm/min
Cuvettes 10 mm square cuvette, 10 – 13 mm round tube, 16mm round tube (option), 50 mm rectangular cell, and 1 inch round tube
Light beam height 8.5 mm at measurement position
Data storage 100 sets
Analog output 0.000 - 4.000 V (option)
Display 16 x 2 large characters LCD
Interface RS232 and parallel printer
Function Initial wavelength, lamp tuning, system validation, resolution
PC software Data collection from saved memory; real time data display and storage
Power 100 – 240 V at 50/60 Hz
Dimension 400(W) x 300(D) x 145(H) mm
Weight 7.5 kg
Ambient temp/humidity room temperature 15 - 35°C, humidity < 80%
Wavelength Range 320-1100 nm
Bandwidth 2 nm
Wavelength Accuracy ± 1 nm
Wavelength Repeatability ± 0.35 nm
Photometric range - 0.300 -3.500 Abs
Measurement mode A/ %T / C
Factor 0.1 - 9,999.9
Photometric Accuracy 1.0% or 0.003A (from 0.000 to 2.500A), whichever is greater
Stability < 0.003A/hr at 500 nm after one hour warm-up
Baseline flatness ± 0.005 Abs (at 400 – 1100 nm)
Stray Light <0.1% at 340 nm by ASTM method
Light Source 12V halogen lamp
Detector Si photodiode
Wavelength scanning speed 4500 nm/min
Cuvettes 10 mm square cuvette, 10 – 13 mm round tube, 16mm round tube (option), 50 mm rectangular cell, and 1 inch round tube
Light beam height 8.5 mm at measurement position
Data storage 100 sets
Analog output 0.000 - 4.000 V (option)
Display 16 x 2 large characters LCD
Interface RS232 and parallel printer
Function Initial wavelength, lamp tuning, system validation, resolution
PC software Data collection from saved memory; real time data display and storage
Power 100 – 240 V at 50/60 Hz
Dimension 400(W) x 300(D) x 145(H) mm
Weight 7.5 kg
Ambient temp/humidity room temperature 15 - 35°C, humidity < 80%